CHARACTERISTICS

ProTech™ 1000 Z2 delivers ppb-level, no-interference H₂S and true total sulfur measurement with ≤20-second predictive alarms. It provides custody transfer–defensible measurement in a compact, uptime-focused tape analyzer.


Benefits

Fast Excursion Alarms
Low ppb sensitivity and predictive alarm analysis deliver industry-leading measurement-to-alarm in <20 seconds.
New Tape Drive System
Improved tape-to-tape repeatability with up to 70 days on a single roll. Front-facing tape system simplifies tape changes and waste removal.
Small Footprint
Lower panel space, easier retrofits, and lighter weight installations. Results in a better fit for compressor stations, metering buildings, and brownfield upgrades.

Communication

Configuration Software
Web browser–based interface for local or remote connection (no installs required).
Modbus
TCP/IP or RTU with user-configurable list.
Analysis Output
  • H₂S (ASTM D4084)
  • True Total Sulfur (with TS option)
Image of the Protech 1000Z2 Product

Application

Range Low: 0 – 100 ppb
Standard: 0 – 300 ppm
High: 0 – 100% with dilution
Lower Detection Limit 5 ppb
Accuracy +/- 2% FS
Repeatability +/- 2% FS
Sensitivity +/- 1% FS
Response Measurement-to-alarm: <20s

Absolute measurement T90:3 min

Certifications

  • CSA/UL: Class I Zone 2, AEx ec db ic op is IIB+H₂ T3 Gc
  • Class I Division 2, Groups BCD T3
  • IECEx: Ex ec db ic op is IIB+H₂ T3 Gc
  • Enclosure: Type 4X / IP68
  • Ambient Temp Rating: 0° to +55°C

Utility Requirements

  • Eductor drive gas
 (air, nitrogen, or sample gas)
  • Hydrogen
 (with Total Sulfur option)

Dimensions

  • Single Stream: 16”h x 12”w x 8”d
  • Multi-Stream: 27”h x 33”w x 8”d
  • Total Sulfur: 34”h x 55”w x 8”d
Ambient Temperature
0° to 55°C (32°F to 131°F)
Sample Gas Consumption
100 sccm (0.21 scfh)
Sample Gas Temperature
0° to 100°C (32°F to 212°F)
LDL
5 ppb
Repeatability
+/- 2% FS
Multi-stream Capability
H₂S: Up to 4
Total Sulfur: Up to 3
Web-based Configuration Software
Yes
Local Display
5" 800×400, full color
Modbus
TCP/IP or RTU
Communication Ports
2× RJ45, 2× RS485
IO Signals
Analog Output, 4–20 mA (x4)
Digital Input, wet or dry (x4)
Dry contact relay (x4)
Dimensions
Single Stream: 16"h × 12"w × 8"d (406mm × 305mm × 203mm)
Multi-Stream: 27"h × 33"w × 8"d (686mm × 838mm × 203mm)
Total Sulfur: 34"h × 55"w × 8"d (857mm × 1394mm × 203mm)
Weight
18 kg (40 lbs) before add-ons and options
Power
24 Vdc, 100W
100–125 Vac, 100W
220–240 Vac, 100W
Total sulfur option: AC-only, 480W Max
Dual redundant AC power with DC backup option
Installation
Fast-loop sample system preferred.
Must be installed indoors or under shelter.
Part Number
Description
CO0200
H₂S Sensing Tape for ProTech 1000, 250 ft (76 m)
CO0082
Humidifier liquid, 4 L
MK0011
H₂S Sample chamber maintenance kit
MK0012
H₂S Sample chamber and TS furnace maintenance kit
MK0013
Arsine / Phosphine Sample chamber maintenance kit
MK0014
Phosgene Sample chamber maintenance kit
MK0015
Chlorine Sample chamber maintenance kit
MC0651Q
Replacement TS furnace tube, quartz
SA2500
Replacement Humidifier
SA2565
ProTech 1000 I.S. Keypad, CSA
SA2992-PT
ProTech 1000 I.S. Keypad, IECEx
QUOTATION REQUEST
Quotation request

Quotation Request Form

Contact us form

"*" indicates required fields

David Haydt

When it comes to solving complex applications challenges for customers, David Haydt has built his stellar reputation as the “go-to guy” over his 28-year career at Galvanic. Dave joined the company in 1993 as an applications technician at Galvanic’s Calgary headquarters. From 1999 to early 2006, he served as a field-service technician based out of Houston, Texas, providing start-up assistance, field repair service, and training to Galvanic’s natural gas transmission, petrochemical and refining industry customers. In 2006, he was promoted to production manager for Galvanic’s gas-analysis products, overseeing all aspects – from design and development of tailored systems to meet the customer’s specific application needs to ensuring on-time delivery of products. In 2015 Dave assumed the role of R&D/applications manager, where he became responsible for Galvanic’s entire line of gas- and liquid-analysis products. In 2021 Dave was promoted to Vice President of Product Innovation. Dave is accountable for the evolution of Galvanic’s entire product portfolio.

Dave started his career as a laboratory analyst for Norwest Laboratories in Alberta, Canada. He holds a bachelor of science degree in chemistry from the University of Calgary.

Steve Aasen

An operations-focused executive with 20+ years of experience driving financial performance in technology-based multi-national companies, Steve Aasen joined Galvanic in late 2014 as director of finance. He came to Galvanic from General Dynamics Canada, Ltd, one of Canada’s largest and most-established defence system integrators, where he served for eight years as director of finance. Earlier, Steve was at Telvent North America, a leading Calgary-based IT and industrial-automation provider for pipeline and energy-utility companies. He started as divisional controller and ultimately served as the company’s chief financial officer. Steve received a bachelor of commerce degree in accounting from the University of Saskatchewan, in Saskatoon, Saskatchewan, Canada. He also earned a CMA Designation from the Society of Management Accountants.

Rene Aldana

A senior business executive with more than 20 years of management experience in the global oil & gas industry, Rene Aldana joined Galvanic as its CEO in June, 2018. Rene has extensive experience in strategic leadership, process automation, talent development, and M&A integration that will benefit the next chapter of Galvanic’s growth and progress. Before coming to Galvanic, Rene was the chief operating officer for ZCL Composites Inc., a TSX-listed composites manufacturing company serving the petroleum, water, and waste water industries. Previously, he was the managing director for Yokogawa Canada, a world leader in industrial process measurement and automation solutions. For 18 years prior, he served in a series of high-profile positions at Telvent, starting in customer service, followed by engineering project management, and culminating as vice president of its International Oil & Gas division. He has a bachelor’s of science in computer science from the Simon Fraser University in Canada, an executive MBA from the IE Business School in Spain, and an ICD.D designation from Canada’s Institute of Corporate Directors. Rene is fluent in English, Spanish (native), and Portuguese.